Send voltage, current, power, and application requirements. An engineer can recommend the right configuration.
300kW/unitParallel expansion up to 3MW
0-2250VDCFor 800V and high-voltage platforms
96A/μs & 150A/μsSlew-rate options available
95% EfficiencyLower heat and energy cost
Dynamic Load Response
30/96/150A/μsSlew Rate Options
Send your voltage, current, and power requirements.
DC load bank for high-power testing
Regenerative electronic load
Built for high-power PSU, battery, PCS, and ATE validation
Fast Transient TestingSlew rates up to 96A/μs & 150A/μs available
High Power Density300kW per unit, parallel expansion up to 3MW
Regenerative LoadReturn energy to the grid instead of wasting it as heat
Configured for Your BenchMatch voltage, current, power, and duty-cycle requirements
Built for high-power labs that need a configurable regenerative load system, not a generic resistor bank
ISO 9001
CE / RoHS
On-site calibration
Custom integration
If you searched for a DC load bank, this is the regenerative option.
FTR7000 is for teams that need programmable high-power loading with energy feedback, fast transient response, and scalable cabinet-level integration.
DC load bank for high-power testingReplace heat-wasting resistor banks in long tests.
Regenerative electronic loadReturn usable energy while testing PSU, PCS, or battery systems.
Programmable DC load testerBuild repeatable profiles for transient and burn-in validation.
3MW scalable load systemStart from 300kW modules and expand in parallel.
Engineered for Extreme Dynamic Load Testing
Power systems can move from idle to heavy load in milliseconds. FTR7000 validates stability under repeatable high-current dynamic conditions.
Slew Rate Options:30A/μs shown, with 96A/μs and 150A/μs configurations available
Extreme Testing:180% overload, 10kHz pulse frequency, up to 100,000 steps
Validates PSU, PCS, BBU, and ATE stability under real operating stress
Helps prevent voltage drop, shutdown, or restart failures
Why regenerative load instead of traditional load banks?
Up to 80% energy regeneration efficiency. Return energy to the grid instead of turning expensive power into heat.
Traditional Load
100kW
Input Power
to heat
100kW
Heat
Heat
High cooling cost Waste energy High operating cost
FTR7000
100kW
Input Power
returned
80kW
Returned to Grid
Grid
Lower electricity cost Reduced HVAC load Ideal for burn-in testing
FTR7000 returns energy to the grid instead of wasting it as heat.
$Reduce electricity cost by up to 80%
ACLower cooling system demand
ROILower total cost of ownership
Key Specifications for Buyer Review
Use these starting points to request a matched voltage, current, and power configuration.
300kW/unitRated power per unit
0-2250VDCHigh-voltage DC platform coverage
96A/μs & 150A/μsHigh-speed slew-rate options available
95% EfficiencyEnergy feedback potential
10kHzPulse frequency support
3MWParallel system expansion
Master-Slave Control:Scale multiple units for cabinet or line-level testing
Programmable Profiles:Build repeatable transient, burn-in, and overload tests
Application Match:PSU, battery, PCS, fuel cell, motor, semiconductor, and ATE
Master
Slave
Slave
Scale from one cabinet to megawatt-level testing.
AI Power Chain Applications
Use FTR7000 where the AI power chain exposes a high-power DC output or needs a repeatable rack-level load. VRM and GPU categories are covered indirectly through upstream PSU, HVDC, and rack-load testing.
AI PSU Module AC/DC and DC/DC load testing
HVDC System 800V and +/-400V sidecar cabinets
BBU Backup Power Li-ion and supercap discharge tests
Rack DC Busbar High-current cabinet bus validation
SST Transformer 800V DC output load validation
Power Generation Gas turbine and SOFC DC loading
SSCE Breaker Microsecond current-step response
VRM Power Stage Upstream PSU transient validation
GPU Compute Load Emulated through PSU and HVDC tests
Engineering Support & On-site Calibration
Share your test conditions before purchase. FaithTech helps specify module count, voltage range, current capacity, integration, commissioning, and calibration.
Buyer Q&A
Quick answers for engineers comparing load-bank, regenerative-load, and high-power DC testing options.
If you searched for a DC load bank, this is the regenerative option.
FTR7000 is for teams that need programmable high-power loading with energy feedback, fast transient response, and scalable cabinet-level integration.
Engineered for Extreme Dynamic Load Testing
Power systems can move from idle to heavy load in milliseconds. FTR7000 validates stability under repeatable high-current dynamic conditions.
Why regenerative load instead of traditional load banks?
Up to 80% energy regeneration efficiency. Return energy to the grid instead of turning expensive power into heat.
Key Specifications for Buyer Review
Use these starting points to request a matched voltage, current, and power configuration.
AI Power Chain Applications
Use FTR7000 where the AI power chain exposes a high-power DC output or needs a repeatable rack-level load. VRM and GPU categories are covered indirectly through upstream PSU, HVDC, and rack-load testing.
Engineering Support & On-site Calibration
Share your test conditions before purchase. FaithTech helps specify module count, voltage range, current capacity, integration, commissioning, and calibration.
Send your voltage, current, and power requirements.
Send voltage, current, power, and application requirements. An engineer can recommend the right configuration.